Contact Us









Nozzles By:
Viking
Reliable
GEM

|
Sprinkler Nozzles
BFPE carries an
enormous variety of nozzles from a wide assortment
of companies. If you don't see it here, ask
us. We can probably get it. BFPE has selected a complete
cross-section of nozzles. If you need assistance in making a nozzle
decision, ask us. We know our nozzles.

Standard Response Sprinklers
Standard response spray sprinklers
are intended for use in fire sprinkler systems designed in
accordance with the standard installation rules recognized by the
applicable Listing or Approval agency. There are two types of
standard response sprinklers – bulb type and solder type.
Universal Model A, Designer, and
Quartzoid® bulb type sprinklers are available in a
variety of attractive finishes that blend well with their
surroundings. When in stand-by service, a small bubble in the fluid
contained in the bulb compensates for normal temperature changes.
When heated, the fluid in the bulb expands and shatters the bulb
which allows water to be discharged. Duraspeed® solder
type sprinklers employ a bell-shaped copper link whose two sections
are joined by solder with a predetermined temperature rating. Heat
absorbed by the link is conducted directly to the soldered joint.
When the solder melts, the link springs apart, releasing water that
strikes the deflector.
Standard response sprinklers are
designed for use in essentially all applications including office
buildings, libraries, banks, theaters, factories, and warehouses.
- Model A, 5 mm, K=2.8,
Pendent and Upright
- Model A, 5 mm, K=5.6
- Pendent and
Upright
- Horizontal
Sidewall
- Vertical Sidewall
- Model A, 5 mm, K=8.0,
Pendent and Upright
- Model A, 5 mm, K=5.6
and 8.0, Recessed Pendent
- F692, 4 mm, K=5.6,
Concealed Pendent
- Issue D, K=5.6,
Pendent and Upright
- F950, K=5.6, Pendent
and Upright
- F950, K=1.4, 2.8 and
4.2, Pendent and Upright
- F950/Q-46, K=5.6,
Horizontal Sidewall 13

Quick Response Sprinklers
Quick response sprinklers are
designed to operate during earlier stages of fire development and
help reduce damage, and enhance life safety. They are available in
pendent, upright, recessed, concealed, vertical sidewall, and
horizontal sidewall styles.
The narrow profile bulbs and
attractive finishes of the Universal Model A provide specifiers with
a wide variety of sprinklers for use in quick response applications.
The Aquarius® Series offers discriminating specifiers the ultimate
in a fusible solder type, low profile, flush style design, and the
versatile Quick Response FR Series provides the specifier with a
solder type sprinkler for most commercial and industrial
applications.
|
|
|
- Model A, 3 mm, K=2.8,
Pendent and Upright
- Model A, 3 mm, K=5.6
- Pendent and Upright,
- Q-71 Horizontal
Sidewall,
- Vertical Sidewall
- Model A, 3 mm, K=8.0,
Pendent and Upright
- Model A, 3 mm, K=5.6 and
8.0, Recessed Pendent
- F690, K=5.6,
Concealed Pendent
- FR-1, K=2.8, Pendent and
Upright
- FR-1, K=5.6, Pendent and
Upright
- FR-1, K=8.0, Pendent and
Upright
- FR-1, K=2.8 and 5.6, Recessed
Pendent
- FR-1/Q-46, K=5.6, Horizontal
Sidewall

Extended Coverage Sprinklers
Extended coverage (EC) sprinklers,
unless otherwise noted, are for the protection of light hazard
occupancies. They are intended for the protection of areas larger than
those specified in standard installation rules. Extended coverage
sprinklers are available in both standard response (EC) and quick
response (QR-EC). They are available in pendent, horizontal sidewall,
and recessed horizontal sidewall. These sprinklers are typically used
in hotels, restaurants, office buildings, and any other large open
area where it is desirable to either have one sprinkler per room or to
reduce the overall number of required sprinklers.
- Model A, 3 and 5 mm,
K=5.6 and 8.0,
- EC and QR-EC,
Horizontal Sidewall
- EC and QR-EC,
Recessed Horizontal Sidewall
- F993, K=5.6, EC and QR-EC
Flush Horizontal Sidewall
- FR-1, K=5.6 and 8.0, EC
and QR-EC, Horizontal Sidewall
- F895, K=11.4 and 14.5,
ECOH, Upright, Pendent and Recessed Pendent
- F890, K=8.0, and K=11.2
ECLH, Pendent and Recessed Pendent 19

Recessed and Concealed Sprinklers
Recessed sprinklers provide a double
benefit. The attractive, recessed design has a more pleasing
appearance in such applications as offices and retail settings. The
design also has a very practical benefit. It allows the sprinkler
system to be installed, tested, and evaluated prior to installation or
finishing of a ceiling or wall. Escutcheon plates, available for these
sprinklers, feature different ranges of adjustability for easy and
neat installation after completion of the ceiling work.
Concealed sprinklers combine the
ultimate in aesthetics with fire protection. The heart of the
concealed assembly is a small-framed sprinkler head contained within
an attractive enclosure that blends with the ceiling for an
unobtrusive and pleasing appearance. The cover plate assembly consists
of an enclosure and a cover plate that is soldered to the enclosure at
three equidistant points around its periphery.
- Model A, 5 mm, K=5.6 and
8.0, Standard Response, Recessed Pendent
- F692, K=5.6, Standard
Response, Concealed
- FR-1R, K=2.8 and 5.6,
Quick Response, Recessed Pendent
- F690 K=5.6, Quick
Response, Concealed
- Model A, 3 mm, K=5.6 and
8.0, Quick Response, Recessed Pendent
- Model A, 3 and 5
mm, K=5.6 and 8.0, EC and QR-EC Recessed Horizontal Sidewall

Special Purpose Sprinklers
Special purpose sprinklers are intended
for use in specific installations. These installations may include the
protection of high-piled storage, freezing and areas subject to
corrosion. Also, these installations may need consideration for more
water at lower pressures, more water over a greater area, or the need
to minimize water damage.
- ESFR-1 and ESFR-25,
K=14.3 and 25.2, Early Suppression Fast Response, Pendent
- EC-25 K=25.2, Extended
Coverage, Uppright
- F892 and F892QR, K=11.2,
Extra Large Orifice, Upright
- F960, K=5.6, Dry
Pendent, Recessed and Upright Sprinkler
- F960/Q-46, K=5.6, Dry
Horizontal Sidewall
- F960/Q-48, K=5.6, EC,
Dry Horizontal Sidewall
- G100, K=5.6, Quick
Response, Institutional
- G102, K=5.6, Quick
Response, Institutional Sidewall
- F890, K=8.0 &
K=11.2, Light Hazard, Pendent
- F898, K=11.2, Large
Drop, Upright
- Rack Storage Sprinklers,
Model A and Issure D
- Rack Storage Sprinklers,
Quick Response Model A and FR-1
- Type 316 Stainless
Steel, K=5.6, Pendent and Upright

Residential Sprinklers
The diverse line of residential
sprinklers are aesthetically pleasing and among the most water usage
efficient in the fire protection industry. Residential sprinklers are
available in pendent, recessed pendent, concealed pendent, horizontal
sidewall, recessed horizontal sidewall, flush pendent, and flush
horizontal sidewall. They are intended for use in one- and two-family
dwellings and mobile homes per NFPA 13D, residential occupancies up to
four stories in height per NFPA 13R, and the residential portions of
any occupancy per NFPA 13. The performance characteristics associated
with residential sprinklers have been proven to help in the control of
residential type fires and, therefore, to improve the chance for
occupants to escape or be rescued.
- F680, K= 3.0, Pendent
- F685, K=3.5 Low Flow
Horizontal Sidewall & Recessed Horizontal Sidewall
- F687, K= 5.8, Horizontal
Sidewall
- F983, K= 4.4, Pendent
- F984, K= 4.4, Horizontal
Sidewall
- F978, K= 4.2, Concealed
Pendent
- F993, K= 5.6, Flush
Horizontal Sidewall

High Pressure Sprinklers
High Pressure Sprinklers are intended
for areas having a maximum service pressure in excess of the
traditional 175 psi (12.1 bar). Their maximum rated service pressure
of 300 psi (20.7 bar) makes them an excellent choice for applications
that otherwise would require the use of a pressure control valve.
Available in either standard or quick
response and in either standard or extended coverage, one of the most
common applications for high pressure sprinklers is in fire protection
systems for high rise buildings.
- Model A300, 5 mm, K=5.6,
Pendent
- Model A300/Q-71, 5 mm,
K=5.6, Horizontal Sidewall
- ModelA300 EC, 5 mm,
K=5.6, Horizontal Sidewall
- Model A300, 3 mm, K=5.6,
Pendent
- Model A300/Q-71, 3 mm,
K=5.6, Horizontal Sidewall
- Model A300 QR-EC, 3 mm,
K=5.6, Horizontal Sidewall

AquaMist® Systems
The Aquamist® Systems
utilize the newest and most unique types of nozzles developed for fire
protection. These systems, in some cases, offer an alternative to
higher density automatic sprinkler systems, or an alternative to Halon
and other gaseous agents such as carbon dioxide, or fixed water spray
systems.
The mechanisms by which the AquaMist
nozzle spray act to extinguish a fire can be a combination of the
following factors, depending on the hazard:
- Heat extraction from
the fire as water is converted into vapor and the fuel is cooled
- Reduced oxygen
levels as the water vapor displaces oxygen near the fire
- Dilution of
flammable vapors by the entrainment of water vapor, to such an
extent that the resultant mixture of vapor will not burn
- Direct impingement
wetting and cooling of the combustibles
- Enveloping of the
protected area to pre-wet adjacent combustibles, cool gases and
other fuels in the area, as well as to block the transfer of
radiant heat to adjacent combustibles
- OH-2 System, AM24
Automatic Nozzles
- Total Compartment Deluge
System
- AM4 Open Nozzles
- AM10 Open Nozzles
- F517 Ready-Riser®
- VSG Waterflow Detector
- F446 Deluge Valve

Spray Nozzles
Spray nozzles are designed for use in a
variety of special hazards applications. Their uses include, but are
not limited to, exposure protection, fire control, fire extinguishment,
and explosion prevention. Many types of nozzles may be required to
provide a properly designed special hazard fire protection system.
- EA-1 Protectospray®
- D3 Protectospray®
- D3 Large Capacity
Protectospray®
- HV (High Velocity)
- F822 through F834
Mulsifyre®
- Ti-Max®
- Cooling Tower

Accessories for Sprinklers and Nozzles
These accessories are for use with the
sprinklers and nozzles described in this catalog. For complete
specifications, installation instructions, and ratings (where
applicable), please refer to the Technical Data Sheet listed after
each product description
- F937 Sprinkler Guard
- F938 Sprinkler Guard
- F700 Recessed
Escutcheons
- F705 Recessed
Escutcheons
- F480 and F481 Clamp-on
Escutcheons
- F740 Sprinkler Cabinet
- Sprinkler Wrenches
- Escutcheons, Pendent and
Sidewall
- F819 Rupture Disc
Assemblies
|