SYSTEMS/Intelligent - MXL Series

MXL-IQ: A member of the InteLINK family of systems designed to make installation and maintenance easier and more efficient through innovative, user-friendly technology. By "intelligently linking" people and technology, these systems allow more end-user participation in the system design and provide an intelligent, custom-engineered solution that reduces cost, increases efficiency and maintains the highest degree of system performance and reliability.

Catalog Sheet #5054

MXL: As the foundation of the MXL Series of systems, the MXL is the most widely accepted analog fire protection system in the marketplace today. With an amazingly flexible architecture, the MXL is the one system that can meet the requirements of a wide range of applications - from the smallest office building, the tallest high rise, the largest convention center, a health care facility, a school or university, airport or a hotel concerned with early warning and evacuation. Flexible and easily expandable at any range, eliminating costly upgrading or retrofitting.

Catalog Sheet #5000

MXLV: The MXLV is a complete package - combining emergency voice evacuation with reliable fire protection. It's the one system that can meet the requirements of a wide range of applications- from the smallest office building, the tallest high rise, the largest convention center, a health care facility, a school or university, airport or a hotel concerned with early warning and evacuation. The flexibility of the MXLV makes it easily expandable at any range, eliminating costly upgrading or retrofitting in the future.


Catalog Sheet #5035

    Features/Benefits of MXL Series

    Installation/commissioning:
    SensorLINK
    Field Programmability
    Field Assembly
    Compare
    CSGM (error checking)
    Diagnostic Software (SIM/Logger)
    One Person Walk Test
    Inventory
    Programmable Relay Bases
    Flexible Architecture
    Factory Based Technical Support

    Reliability
    Circuit Design
    ISO 9001 Certification
    Alarm Verification
    Intelligent Analog Detection
    Dynamic Supervision
    EnviroLINK
    Detector Design (RF immunity etc.)
    Dynamic Network Integrity
    ChronoLINK
    Distributed Processing
    Class A, Style 7
    LIM-1 Short Circuit Isolation
    Rapid System Response
    CXL Central Monitoring

    Flexibility/Expansion
    Large System Capacity
    Modular Design/Field Assembly
    Distributed Processing
    Integrated Voice
    Multiple Command Centers
    LifeLINK
    CXL
    Hybrid Detection
    Peripheral Support (printers, VDTs, graphics, etc.)
    Wiring Configurations (Style 4, 7, A, B, Star, Bus, Loop)
    Foreign System Interface
    Extinguishing Agent Releasing

    Life Cycle Cost
    Easy Expansion/Modular
    Backward Compatibility
    Feature Upgrades/Software
    SupportLINK
    Sales Outlet Choice

    Operation
    Menu Driven Operator Commands
    User Help Screens
    Easy to Use Control Key Layout
    80 Character LCD Display
    Programmable Function Keys
    Integrated Voice
    Easy Sensitivity Check/Change
    Dirty Detector Indication
    Password Protection
    Automatic Time Based Control
    Rapid System Response
    Customer Training

    Listings/Approvals
    NFPA 72 Compliance
    UL Listed 864,1076
    ULC
    CSFM
    City of Chicago
    NYMEA
    FM
    Coast Guard Approved

 
Go to the Top


SYSTEMS/Intelligent - MXL-VDT

MXL-VDT: The MXL-VDT is a 14" video monitor with detachable keyboard, it provides an interactive terminal for secondary display of MXL information, and operation of MXL functions such as Acknowledge, Silence, and Reset as well as arming and disarming devices. It also provides a means for generating system reports such as listing smoke detector sensitivity settings and voltages, battery and power supply voltages and current.

Catalog Sheet #5016    

CP-2ER: The Siemens Fire Safety Control ModelCP-2ER is a two-zone local control unit which meets the requirement of NFPA 72 or a two -zone releasing device panel approved in accordance with NFPA 72, 12A, 13, and 2001 for cross zone protection. When the CP-2ER control Panel is used as a releasing device, two Class A or Class B detection circuits are arranged so that both zones must be activated in order to discharge the agent automatically into the protected area.

Catalog Sheet #6015   

 

SYSTEMS/Command Center Systems
SYSTEMS/Intelligent - CXL

CXL: When a fire protection system consists of a number of individual control panels - either in a single large facility or in many buildings spread over campus or complex - it is often desirable to monitor, maintain or control those panels from a single, central location.
The Siemens Fire Safety CXL command center provides a reliable, user-friendly, cost-effective means of monitoring alarm and trouble, as well as other information from up to 28 individual MXL or XL fire protection control panels.

In addition, it allows keyboard control of each panel, enabling the operator to acknowledge events, silence audible signals, reset the systems, disable devices, activate relays, change detector sensitivity settings, generate maintenance reports and perform many other functions, from within the facility, across the street, across the campus, across the city or around the world.

The CXL consists of a color video display terminal - with keyboard, a printer, and a set of integral modems used to communicate with plug-in modems located in the MXL and XL3 control panels. Communication can occur over a single pair of wires, such as dedicated phone lines. It can also occur using data grade lines, or even fiber optics, with distances being virtually unlimited. For the highest level of fault tolerance, redundant (Style 7) communication paths are available.

Features/Benefits of CXL Series
  • Fire command center
  • Over 100,000 input points
  • Monitoring and control of MXL and XL3 control panels
  • Color video display terminal
  • Color graphics option
  • Redundant communication paths
  • System diagnostics and maintenance reports including smoke detector sensitivity readings
  • 8 miles between units over standard twisted pair wire
  • Multilevel operator password protection
  • Unlimited distance using data grade phone lines
  • Fiber optic communication option
  • Supervised printer
  • UL/ULC listed, CSFM, City of Chicago

Catalog Sheet #3510

 CXL-G/GT

CXL-G/GT is an interactive color graphics system can be provided for the CXL. The graphics option permits the display of floor plans, operator instructions, even scanned photographs, and up to 10 screens or "zoom" levels for each and every detector in the complex. The graphics option also provides a keyboard for execution of all operator commands and acts as a historical logging unit, recording all system activity on a hard disk drive. The event log capacity is virtually unlimited. A touch screen is also available to enhance its ease of use.

Features/Benefits Graphical Operator Interfaces
  • Color Graphics:
  • Graphic Display of System Conditions
  • Event Display by Color
    High Resolution Color Monitor
  • PC Based
  • Interactive terminal Mode
  • Complete History Log w/Report Generation
  • Color Printer Support
  • Automatic and Manual
  • Graphic Screen Printing
  • 10 Levels of Zoom For Each Detection Device
  • Touch Screen Support
  • Uses Exicisting CAD Drawings Regardless of Format
  • Icon Library w/Custom
  • Icon Editor
  • Special Instruction Field
  • Fully Supervised
  • File Consistancy Reports
  • Password Protection

Catalog Sheet #3516   

FireFinder (NCC-G, NCC-T, NCC-GL)

FireFinder is a PC based color graphics display and control software package designed for use with the Siemens Fire Safety LifeLINK life safety system network. It is used to monitor alarms, supervisories, troubles, securities and any other events detected and reported by autonomous MXL systems.


Catalog Sheet #5068    

 

Go to the Top

SYSTEMS/Conventional

System 3: Introduced in the late 1960s, System 3 is the most successful system ever from Siemens Fire Safety. At the time it revolutionized the concept of modular design, which enabled each system to be specifically designed and customized to meet the customers application needs. System 3 continues to endure as one of the most popular systems, due to its inherent simplicity and reliability.

Catalog Sheet #3060        

PXL: The PXL fire alarm system offers every building owner fire protection which is easy to install, easy to use and cost effective in every application. Buildings which require reliable fire protection at low cost are quickly satisfied by the PXL, the only conventional fire alarm system utilizing detection and control products from the same manufacturer. Many facilities require conventional fire detection in 12 to 16 zones or more, but do not require the increased capabilities of intelligent detection. PXL offers a cost effective solution for schools, nursing homes, apartment buildings, municipal buildings, department stores, strip malls, and more. This system will provide basic, reliable smoke and heat detection, monitor status of sprinkler systems, send evacuation signals throughout the building and transmit system condition to a central station. And it can be tailored to do so for any variety of specific needs.


Features/Benefits of PXL Series

    LCD Display
    System Status LEDs
    Alphanumeric Keypad
    Conventional Input Zones
    Notification Appliance Circuits
    Relays
    Custom Messages
    Alarm Verification
    History Log
    Bypass Inputs and Outputs
    One Person Test
    Password Protection

Catalog Sheet #8100    

SYSTEMS/Suppression

SXL-EX: The SXL-EX is the most basic member of the Siemens Fire Safety family of fire alarm control systems. Incorporating innovative, high quality design, SXL-EX will provide years of reliable fire protection in small buildings and structures. The SXL-EX was developed to meet the varied fire detection needs of schools, municipal buildings, nursing homes, apartment buildings, warehouses, small office buildings and department stores, virtually anywhere a cost efficient, general purpose fire control panel is required.

    Features/Benefits of SXL-EX Series

  • 4 Zones-Expandable to 8 Zones
  • Microprocessor Based Control
  • Factory Programmed Field Configurable 
  • Series 3 and Series 11 Compatible Detectors and Accessories * NEW
    2 Style Y Notification Appliance Circuits Multi-Option Programmable
  • 3 Amps indicating and Auxiliary Power
  • 24 and 60 hour Battery Backup
  • Subsequent Alarm and Trouble with 24 hour reminder
  • 8 Form C Relay Output Option
  • 220/240 VAC, 50 HZ Power Supply Option
  • Remote Serial Annunciator Option
  • Sprinkler supervisory Service
  • One person Test Feature
  • Non-Silenceable Bell Service * NEW
  • Alarm Verification by Zone * NEW
  • Zone/Output bypass Feature
  • UL/ULC Listed
  • 230 Vac/50 HZ Power Supply Option
  • Inherently Power Limited Per NEC 760
  • Alarm, Trouble and Supervisory Last Event Records
MODEL# DESCRIPTION CAT. #
SRC-8 8 Relay Output Module 7902   
LED-3 Remote Annunicators 7903   
SLT-1 Leased Line/Municipal Tie Module 7905   
SXL-EX Conventional Zone Fire Alarm Control Panel 7906   
SZE-4X Zone Expansion Module for SXL-EX 7907  
SZE-8AX Class A Expander Module for SXL-EX 7908

Go to the Top

VoiceCom: The VoiceCom voice and tone alarm emergency communication system is the ideal solution for voice evacuation requirements in small to mid-size applications. Recent trends indicate that future fire alarm/suppression systems will use more voice communications to better manage the evacuation of facilities during fire and other emergencies. VoiceCom provides the answers all the emerging voice and tone communication needs such as NFPA's "new assembly occupancy" requirements.

Features/Benefits of VoiceCom
  • UL listed 864
  • CSFM, NYMEA Approved
    ULC Listed
  • Style Y(class B) and SyleZ (class A) speaker and strobe circuits
  • Power Supply and Battery Charger with output over-voltage protection
  • Dry contact or polarity reversal activation
  • Fully supervised activation inputs
  • High efficiency digital amplifier
  • True 50 and 100 Watt RMS output
    25 or 70 VRMS audio (Field selected)
  • ADA strobe circuits
  • Full dead front enclosure
  • Power limited outputs
  • Stand-alone or Fire
  • Alarm/Suppression system activation
  • Field programmable digital
  • MessageMaker
  • Coded tone option
  • Backup evacuation tone option
  • Backup amplifier option
  • Auxiliary power supply/batter charger option
  • Short circuit isolation
  • Small light weight construction

Catalog Sheet #3700    